Ventara
Visit Ventara Store

Ventilation for the wayIndia builds today.

Energy-recovery ventilators, heat-recovery units, and ducted systems, engineered for Indian humidity, dust load, and grid conditions. Sized for studios, schools, and skyscrapers.

Our range

Pick a category,
find the right fit.

Six categories. One engineering standard. Every product sized for Indian humidity, dust load, and grid conditions.

VentoFresh Pro 250 render
Residential · Energy Recovery

VentoFresh Pro 250

Wall-mounted energy recovery ventilator for 2–4 BHK apartments. 250 CMH continuous fresh air, HEPA-13 filtration, counter-flow enthalpy core recovering up to 82% of energy.

250 CMH
airflow
82%
recovery
HEPA H13
filtration
38 dB
noise
AeroLine Inline 200 render
Concealed · High-static-pressure

AeroLine Inline 200

In-ceiling inline fan with high static pressure for tight ducted runs. Variable-speed low-noise EC motor for residential and small-commercial fresh-air or exhaust circuits.

200 CMH
airflow
350 Pa
staticPressure
EC variable
motor
IP44
enclosure
PureRoom 120 render
Wall-mounted · Single-room

PureRoom 120

Single-room fresh-air fan with three-stage filtration. Delivers up to 120 CMH of filtered outdoor air to one bedroom, study or studio. Whisper-quiet night mode.

120 CMH
airflow
F7 + H13
filtration
28 dB
noise
Wi-Fi app
control
QuietExtract 150 render
Kitchens · baths · utility

QuietExtract 150

Domestic exhaust fan with backdraft damper for moisture and odour extraction in kitchens, bathrooms and utility rooms. Run-on timer and humidistat options.

150 CMH
airflow
28 dB
noise
IPX4
enclosure
Timer + humidistat
control
AeroCore X 2500 render
Commercial · High-airflow

AeroCore X 2500

High-airflow cabinet unit for offices, malls, schools and factories. 2,500 CMH, BMS-integrated, demand-controlled with CO₂ sensors at every zone.

2,500 CMH
airflow
85%
recovery
EC variable
motor
BMS
integration
Filters & Controllers render
Filters · sensors · controllers

Filters & Controllers

HEPA H13 replacement cartridges, CO₂ sensors, room controllers, grilles and ducting accessories that keep every Ventara system running at spec.

HEPA H13
grade
CO₂
sensors
MERV-13
prefilter
5-yr plan
service
03Technical specifications

Engineered for
Indian conditions.

Dust load, monsoon humidity, voltage fluctuation, every component spec’d for the real grid, not the lab grid.

Airflow
100 – 2,000 CMH
configurable by model
2,000CMH
Energy recovery
Up to 82% sensible · 70% latent
enthalpy wheel core
82%
Filtration
G4 + F7 + HEPA H13
multi-stage, replaceable
H13
Noise level
38 – 52 dB across speed range
quietest at night mode
38dB
Power
220 V · 50 Hz · 80 – 320 W
EC fan, variable
220V
Warranty
5 years on core · 2 years on motor
nationwide service
5yrs
04Solutions showcase

Products in the field.
Real installations.

Selected projects and product pairings that show how Ventara equipment is applied across apartments, schools, gyms, hotels and offices.

VentoFresh Pro 250 photo
Residential · 4 BHK · Delhi

VentoFresh Pro 250

250 CMH energy recovery ventilation with HEPA H13 for apartment comfort and low CO₂.

Request similar
AeroCore X 2500 photo
School · Bengaluru · Feb ’24

AeroCore X 2500

Ducted recovery ventilation for classrooms and labs with outdoor-air balancing.

Request similar
AeroLine Inline 200 photo
Gym · Delhi · Jul ’24

AeroLine Inline 200

High static pressure inline fans for fresh-air delivery in high-activity zones.

Request similar
PureRoom 120 photo
Hotel · Goa · Mar ’24

PureRoom 120

Targeted room-level fresh-air distribution with quiet night mode.

Request similar
Filters & Controllers photo
Office · Pune · Sep ’23

Filters & Controllers

HEPA filtration and CO₂ monitoring across multi-floor commercial systems.

Request similar
Knowledge

Questions about sizing & systems

What is an ERV and how is it different from an air conditioner?

An Energy Recovery Ventilator (ERV) brings filtered fresh outdoor air in and pushes stale indoor air out, exchanging heat and humidity through a recovery core. An air conditioner only recirculates and cools the same indoor air. It does not remove CO₂, VOCs or bioaerosols. Cooling without ventilation concentrates those contaminants; an ERV removes them.

Do I need ventilation if my home is open-plan or has windows?

Yes. Open layouts move air sideways but do not exchange it, so CO₂ and off-gassing still accumulate. Opening windows in most Indian cities swaps indoor CO₂ for outdoor PM2.5 that is 6–10× the WHO safe range. Mechanical ventilation with HEPA filtration delivers fresh air without that trade-off.

What airflow (CMH) do I need for my space?

As a rule of thumb, target roughly 30 m³/hour of fresh air per person, adjusted for room volume and use. Ventara sizes every system to the actual square footage, occupancy and building type. Share your details on the contact form and we return a sized system, price band and timeline, usually within 24 hours.

Are Ventara systems built for Indian conditions?

Every product is spec’d for Indian dust load, monsoon humidity and voltage fluctuation, with G4 + F7 + HEPA H13 multi-stage filtration and EC motors that tolerate real-grid conditions, not lab conditions.

Do you install, or is it self-install?

Both. Residential ERVs are available for self-install through the online shop with engineer support, and we have 120+ authorised installers across 25+ cities for full sizing, install and service.

What warranty and service do you offer?

Ventara systems carry a 5-year warranty on the recovery core and 2 years on the motor, with nationwide service and a 5-year filter/accessory service plan.

Chat on WhatsApp